41.
If eddy current damping is to be used, the disc of instrument should be
Answer: Option
Explanation:
Disc must be conducting otherwise eddy currents can not flow. It must be non-magnet, i.e., so that it does not affect the measurement.
42.
The scale of moving iron instrument is linear.
Answer: Option
Explanation:
Since reading is proportional to I2, the scale is non-linear.
43.
With a variable reluctance tachometer having 60 rotor teeth the count reads 3600 counts per minute. The speed in RPM is
Answer: Option
Explanation:
If speed is 60, the counter will count 60 x 60 = 3600 counts/per minute.
44.
When measuring phase angle between two waves using a CRO, the time base generator is connected to
Answer: Option
Explanation:
Time base signal is not connected. The two waves are fed to X and Y plates respectively.
45.
It is required that a strain gauge has gauge factor of 100. The proper strain gauge is
Answer: Option
Explanation:
Only semiconductor strain gauge can have a gauge factor of 100. For all other strain gauges, gauge factor is about 2 only.