21.
Assertion (A): Wien bridge can be used for measuring frequency.
Reason (R): A frequency meter for 50 Hz system has a frequency range of 40 to 60 Hz.
Answer: Option
Explanation:
Frequency range is 47 to 53 Hz.
22.
Which of these has poor overload capacity?
Answer: Option
Explanation:
The wire is very delicate and has little over load capacity.
23.
In 3 phase power measurement by two wattmeter method, both wattmeters had equal reading. The power factor of load is
Answer: Option
Explanation:
Readings of two wattmeters are same when σ = 0 or p.f. = 1.
24.
Which instrument is based on induction principle?
Answer: Option
Explanation:
Energy meter is also based on induction principle.
25.
Magnetic field intensity has the dimensions
Answer: Option
Explanation:
Magnetic field intensity = MMF/length = IL-1.