Online Chemical Engineering Test - Process Control and Instrumentation Test 1

Instruction:

  • This is a FREE online test. Beware of scammers who ask for money to attend this test.
  • Total number of questions: 20.
  • Time allotted: 30 minutes.
  • Each question carries 1 mark; there are no negative marks.
  • DO NOT refresh the page.
  • All the best!

Marks : 2/20


Total number of questions
20
Number of answered questions
0
Number of unanswered questions
20
Test Review : View answers and explanation for this test.

1.
Volumetric expansion is the working principle of the __________ thermometers.
mercury in glass
constant volume gas
vapor pressure
bimetallic
Your Answer: Option
(Not Answered)
Correct Answer: Option

2.
Compositional analysis of __________ is done using mass spectrometer.
an isotope
natural gas
a solid
an alloy
Your Answer: Option
(Not Answered)
Correct Answer: Option

3.
A magnetic flowmeter is
based on the principle of Faraday's law.
capable of measuring the flow rate of slurries and electrolytes.
based on the linear relationship between the fluid flow rate and the induced voltage.
all (a), (b) and (c).
Your Answer: Option
(Not Answered)
Correct Answer: Option

4.
The __________ of a vapor pressure thermometer is a primary element.
pointer
Bourdon tube
bulb
none of these
Your Answer: Option
(Not Answered)
Correct Answer: Option

5.
The transfer function for a P-D controller is
Kc(1+τD s)
Kc(1 +1/τD s)
Kc τD s
KcD s
Your Answer: Option
(Not Answered)
Correct Answer: Option

6.
High temperature of around 2000°C of incandescent gas mantles is measured by a/an
specially designed thermocouple.
optical pyrometer.
radiation pyrometer.
none of these.
Your Answer: Option
(Not Answered)
Correct Answer: Option

7.
What is the dynamic error in a critically damped second order instrument for a ramp input (At) ?
0.5 AT
2 AT
AT
1.5 AT
Your Answer: Option
(Not Answered)
Correct Answer: Option

8.
Emf generated in a thermocouple depends on the temperature
of cold junction only.
of hot junction only.
difference between hot and cold junctions.
difference between cold junction and atmospheric temperature.
Your Answer: Option
(Not Answered)
Correct Answer: Option

9.
__________ stability method uses open loop transfer function.
Nyquist
Mikhalov
Ruth
none of these
Your Answer: Option
(Not Answered)
Correct Answer: Option

10.
Thermal conductivity based continuous flue gas analyser makes use of varying thermal conductivity of the constituents of flue gases. Which of the following constituents of flue gases has the maximum thermal conductivity ?
CO2
N2
O2
CO
Your Answer: Option
(Not Answered)
Correct Answer: Option

11.
Mercury thermometer can be used to measure the temperature upto __________ °C.
100
250
350
750
Your Answer: Option
(Not Answered)
Correct Answer: Option

12.
Liquid levels in autocalves are measued by
simple float
differential float type manometer
glass gauge
none of these
Your Answer: Option
(Not Answered)
Correct Answer: Option

13.
Small furnace draught is accurately measured by an inclined tube manometer, in which the manometric liquid used most commonly is
water
carbon tetrachloride
paraffin
ethylene glycol
Your Answer: Option
(Not Answered)
Correct Answer: Option

14.
Which is the symbol for "pneumatic control valve" ?
none of these
Your Answer: Option
(Not Answered)
Correct Answer: Option

15.
Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an
orsat apparatus
thermal conductivity cell
zirconia probe
chromatograph
Your Answer: Option
(Not Answered)
Correct Answer: Option

16.
Photoelectric pyrometers are suitable in the temperature range of __________ °C.
400-1600
800-1600
800-2500
400-1000
Your Answer: Option
(Not Answered)
Correct Answer: Option

17.
Nickel percentage in invar which is an iron-nickel alloy, and is used as a thermocouple material is
12
36
54
68
Your Answer: Option
(Not Answered)
Correct Answer: Option

18.
Gain margin is equal to the
amplitude ratio
reciprocal of amplitude ratio
gain in P controller
gain in P-I controller
Your Answer: Option
(Not Answered)
Correct Answer: Option

19.
A manometer measures the __________ pressure.
atmospheric
absolute
gauge
none of these
Your Answer: Option
(Not Answered)
Correct Answer: Option

20.
A first order system with unity gain and time constant τ is subjected to a sinusoidal input of frequency w = 1/τ. The amplitude ratio for this system is
1
0.5
1/2
0.25
Your Answer: Option
(Not Answered)
Correct Answer: Option

*** END OF THE TEST ***
Time Left: 00:29:56
Post your test result / feedback here: